Biology Articles » Cryobiology » Sperm cryopreservation: is there a significant risk of cross-contamination? Sperm cryopreservation: is there a significant risk of cross-contamination?OpinionsSperm cryopreservation: is there a significant risk of cross-contamination?Gary N. ClarkeAndrology Department, The Royal Women's Hospital, Carlton, Victoria 3053, Australia Interest in the subject of sperm cryopreservation has a long history, with thousands of published articles in the scientific/medical literature. Clinical pregnancy rates using donor insemination can now approach natural pregnancy rates (Clarke et al., 1997b ). However, an issue which has received very little attention in the literature is the subject of microbiological cross-contamination in sperm banks. This subject obviously concerns many sperm bank managers, who have instituted several approaches aimed at reducing the perceived risks. One approach is to screen all patients or donors for human immunodeficiency virus (HIV) status, hepatitis B and C and syphilis prior to cryopreservation of their semen. Another approach involves the use of quarantine tanks to hold samples until screening results are obtained, before placing the cleared samples into the main storage system. The samples of patients with positive screening results are then transferred to specially designated tanks. Both of these approaches have obvious drawbacks because of the incubation period of HIV and the fact that the screening procedures do not cover all potential pathogens. This issue therefore needs to be addressed from another perspective in order to estimate the likelihood of its occurrence and to determine what measures, if any, might be considered appropriate to prevent or minimize it. The occurrence of cross-contamination during liquid nitrogen storage of biological material and subsequent cross-infection of patients has previously been demonstrated (Tedder et al., 1995 Traditionally, semen storage protocols have not involved sterile techniques. In particular, filling of straws by the `dip and wipe' procedure (Russell et al., 1997 Consideration of the evidence presented above of liquid nitrogen contamination by microbes, and the common use of cryovials which absorb liquid nitrogen, leads to the conclusion that cross-infection via the clinical use of cryopreserved semen is a realistic possibility. As in any other area of clinical medicine, a significant risk of cross-infection should be taken seriously and if possible, steps taken to minimize it. Fortunately there are a number of relatively simple details and possible changes to cryopreservation procedures which would minimize the potential for contamination or cross- contamination of stored sperm samples. Sealing of straws or vials Adequate sealing is obviously vital. Straws can be heat-sealed at both ends, or extra attention paid to PVA powder sealing. Thus, it is important to draw the semen–cryoprotectant mixture through the inner cotton plug so that it contacts and sets the PVA powder between the inner and outer cotton plugs. At the opposite end of the straw it is important to leave an air-gap of at least 1 cm to allow for expansion during freezing, with the PVA powder set by dipping the straw end in water for several minutes. A new straw system, Cryo Bio System (CBS; http:II cryobiol.system- IMV.com) produced by IMV Technologies (L'Aigle, France) will also minimize the possibility of contamination because it is made from a shatter-proof ionomeric resin, uses a loading manifold to prevent contact between the straw and semen and allows for heat sealing at both ends. Microbiological tests on the CBS straws suggested that they provided a highly efficient seal against entry or egress of micro-organisms. These tests were conducted or supervised by Dr Bernard Guerin (Laboratoire Pour Le Controle Des Reproducteurs, Ministere de L'Agriculture, BP65.13, rue Jouet-94703 Maisons-Alfort Cedex, France). In contrast, cryovials definitely do not maintain their seal under liquid nitrogen – they should be stored inside a second skin such as Cryoflex (Nalge Nunc International) or stored in the vapour phase only, as discussed below. Liquid nitrogen vapour storage Previous studies have shown that human semen can be stored at temperatures as high as –79°C for up to 1 year while retaining motility and fertilizing capacity. Thus, one author (Sawada, 1964 In order to overcome the inconvenience of using Cryoflex and the problem of leaking vials if stored in the liquid phase, we have recently developed a one-step liquid nitrogen vapour cooling / storage system which gives on average, >50% motility recovery. This is a very simple system wherein the semen–cryoprotectant mixture is divided into aliquots in cryovials which are then put into capped polypropylene test tubes (Product No. 55.510; Sarstedt, Ingle Farm, South Australia). The test tubes are placed in the upper goblet of a liquid nitrogen tank (35HC; Taylor Wharton, Theodore, Alabama, USA) containing ~15 cm depth of liquid nitrogen, for both cooling and ongoing storage. The average cooling rates from room temperature to –190°C (liquid nitrogen vapour) ranged from 10–20°C/min depending on the number of vials per storage tube. The vials are thawed in air at 37°C. Initially, we had observed that the vapour temperature in a narrow- necked tank (35HC; Taylor Wharton Theodore) was quite stable at around –190°C when measured 12 times over a period of 3 months. This suggested that medium- to long-term storage in vapour was feasible. For laboratories using wide-necked storage tanks the use of aluminium racks or conductive rods (e.g. aluminium canes) could potentially minimize the temperature gradient so that the vapour temperature is around –190°C near the top of the storage space (Rowley and Byrne, 1992 Considering the stable, low temperatures achievable with vapour storage and the early work using dry-ice storage, there was no a priori reason not to use this system. We have now used this procedure to store sperm samples for backup for intracytoplasmic sperm injection (ICSI) treatment for the last 2.5 years. During this period, spermatozoa from 70 patients have been stored and 21 of these patients have subsequently had cryopreserved spermatozoa used for ICSI. Of the 21 patients, nine used either testicular or epididymal spermatozoa. Overall, a normal fertilization rate of 56% was obtained, with 91% undergoing cleavage. Embryos were transferred to 20 patients in 37 cycles (approximately two embryos/cycle), resulting in six patients with raised ß-human chorionic gonadotrophin (HCG) and four with clinical pregnancies by fetal heart (FH) detection (6.1% FH implantation rate per embryo transferred; 20% of patients pregnant). These results are equivalent to our overall ICSI results (Clarke et al., 1997a Other recommended precautions When using PVA sealing powder, it is important to aliquot it into tubes which can be used for one patient only. Tamping straws from different patients into the same powder could result in cross- contamination (Russell et al., 1997 On thawing for clinical use, any straws which are obviously cracked or have lost their seal at either end should be discarded. In addition, the outside of straws should be sterilized (e.g. by hypochlorite) prior to cutting with sterile scissors or scalpel blade to extract semen for assisted reproductive technologies (ART). Prior to freezing or clinical use, labelling on straws/vials should always be checked and records countersigned by a second staff member, or the patient. Only one semen sample should be processed for cryopreservation at a time at a workstation separated from other biological samples (e.g. semen samples for analysis or blood for sperm antibody testing). Conclusions Considering the significant potential for cross-contamination during semen cryostorage using current methodology, and consequently the finite (but probably unquantifiable) risk of cross-infection during ART procedures, I would urge that sperm banks critically examine all of their procedures with the aim of eliminating this risk at the outset. Why continue with suboptimal procedures until a patient contracts a serious illness from cross-infection, as has occurred with bone-marrow storage? Quarantine tanks have some merit but, on their own, they are not an adequate solution because patients may be carrying viruses which have not been tested for. Acknowledgments The author thanks Jing Hong An, Peter Elliott and Henry Oh for performing the cryopreservation procedures, and Anne McCartin for typing the manuscript. Notes This opinion was previously published on Webtrack 85, September 10, 1999 References Ackerman, D.R. (1968) Damage to human spermatozoa during storage at warming temperatures. Int. J. Fertil., 13, 220–225. Charles, C.R. and Sire, D.J. (1971) Transmission of papillomavirus by cryotherapy application. J. Am. Med. Assoc., 218, 1435. Clarke, G.N., Hyne, R.V., Du Plessis, Y. et al. (1988) Sperm antibodies in human in vitro fertilization. Fertil. Steril., 49, 1018–1025. Clarke, G.N., Bourne, H. and Baker, H.W.G. (1997) Intracytoplasmic sperm injection for treating infertility associated with sperm autoimmunity. Fertil. Steril., 68, 112–117. Clarke, G.N., Bourne, H., Hill, P. et al. (1997) Artificial insemination and in-vitro fertilization using donor spermatozoa: a report on 15 years of experience. Hum. Reprod., 12, 722–726. Fountain, D., Ralston, M., Higgins, N. et al. (1997) Liquid nitrogen freezers: a potential source of microbial contamination of hematopoietic stem cell components. Transfusion, 37, 585–591. Goodman, J. (1960) Liquid nitrogen therapy of warts and other skin lesions. Can. Med. Assoc. J., 82, 628–630. Hawkins, A.E., Zuckerman, M.A., Briggs, M. et al. (1996) Hepatitis B nucleotide sequence analysis: linking an outbreak of acute hepatitis B to contamination of a cryopreservation tank. J. Virol., Methods, 60, 81–88. Hildebrant, R.J., Sever, J.L. and Anderson, B. (1968) Preservation of infectious cytomegalovirus. Proc. Soc. Exp. Biol. Med., 129, 504–506. Johnston, R.C., Clarke, G.N., Liu, D.Y. et al. (1995) Assessment of the sperm quality analyzer. Fertil. Steril., 63, 1071–1076. Jones, S.K. and Darville, J.M. (1989) Transmission of virus particles by cryotherapy and multi-use caustic pencils: a problem to dermatologists?Br. J. Dermatol., 121, 481–486. Meryman, H.T. (1963) Preservation of living cells. Fed. Proc., 22, 81–89. Rowley, S.D. and Byrne, D.V. (1992) Low-temperature storage of bone marrow in nitrogen vapor-phase refrigerators: decreased temperature gradients with an aluminium racking system. Transfusion, 32, 750–754. Russell, P.H., Lyaruu, V.H., Millar, J.D. (1997) The potential transmission of infectious agents by semen packaging during storage for artificial insemination. Animal Reprod. Sci., 47, 337–342. Sawada, Y. (1964) The preservation of human semen by deep freezing. Int. J. Fertil., 9, 525–532. Schafer, T.W., Everett, J., Silver, G.H. et al. (1976) Biohazard potential: recovery of infectious virus from liquid nitrogen of a virus repository. Health Lab. Sci., 13, 23–24. Tedder, R.S., Zuckerman, M.A., Goldstone, A.H. et al. (1995) Hepatitis B transmission from contaminated cryopreservation tank. Lancet, 346, 137–140.
Source: Human Reproduction, Vol. 14, No. 12, 2941-2943, December 1999. rating: 0.00 from 0 votes | updated on: 17 Feb 2007 | views: 110 | |

© Biology-Online.org. All Rights Reserved. Register | Login | About Us | Contact Us | Link to Us | Disclaimer & Privacy
Science Network - Braintrack.com - University Directory | Chemicool.com - Chemistry | EquationSheet.com - Equations